Scantronic 4603 Guia do Utilizador

Consulte online ou descarregue Guia do Utilizador para Sistemas de segurança - controlo de acesso Scantronic 4603. Scantronic 4603 User guide [en] Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 12
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 0
496368 Issue 1 1 of 12
4600
Installation and User Guide
Compatible Equipment
4601 Long range and short range pendant transmitters
4602 Hand held PA
4603 Programmable transmitter
4604 Contact transmitter
4605 Short range dual channel transmitter
4608 PIR
4609 Smoke detector
7150 Viper radio vibration detector (supplied by Weyrad Elec-
tronics).
Vista de página 0
1 2 3 4 5 6 ... 11 12

Resumo do Conteúdo

Página 1 - Installation and User Guide

496368 Issue 1 1 of 124600Installation and User GuideCompatible Equipment4601 Long range and short range pendant transmitters4602 Hand held PA4603 Pro

Página 2 - Technical Specification

10 of 12 496368 Issue 1Figure 5. Fault Finding Displays ContinuedRemote setting transmitterjammed on. Check forobvious causes, e.g. testswitch turned

Página 3 - Programming

496368 Issue 1 11 of 12User CommandsFrom the KeypadFull Set User code + 2Unset User codePart Set User code + 1Omit Zones User code + 2 + OMIT + zone n

Página 5 - Defaults

2 of 12 496368 Issue 1IntroductionThe 4600 electronic intruder alarm system is a fully programmable, 8-zone,bells only, radio security system, designe

Página 6 - Engineering Program Commands

496368 Issue 1 3 of 12WiringFigure 1. External SAB Bell/Strobe and Internal Speaker ConnectionsNotes:1. SAB shown for negative applied. The connection

Página 7 - 496368 Issue 1 7 of 12

4 of 12 496368 Issue 1Figure 2. Setting the Site CodeConsult the sections for individual 4600 series transmitters for detailson setting the DIL switch

Página 8 - Walk Test

496368 Issue 1 5 of 12Programming CommandsTo change the factory default program use the commands listed in thissection as follows:1. Key in the comman

Página 9 - Fault Finding

6 of 12 496368 Issue 1Zone 1 Entry/Exit zone/part set/auto restore (PIR)Zone 2 Part set/entry route zone/auto restore (PIR, VIPER)Zone 3 Part set/entr

Página 10 - 10 of 12 496368 Issue 1

496368 Issue 1 7 of 12To change: Key in: Then: Notes DefaultZone Options 5n ENTER 1 = Double knock(n = zone number) 2 = Chime3 = Auto RestorePress Cle

Página 11 - User Commands

8 of 12 496368 Issue 1Leaving Programming ModeWhen all programming is complete:1. Remove the programming stencil and close the panel.2. Key in 99 then

Página 12 - 12 of 12 496368 Issue 1

496368 Issue 1 9 of 12Fault FindingUnder normal operating conditions, the Fault and Alarm LEDs are dark (thepower LED glows while mains is on). The Wa

Comentários a estes Manuais

Sem comentários