6 of 12 496368 Issue 1
Zone 1 Entry/Exit zone/part set/auto restore (PIR)
Zone 2 Part set/entry route zone/auto restore (PIR, VIPER)
Zone 3 Part set/entry route zone/auto restore (PIR, VIPER)
Zone 4 Auto restore (PIR, VIPER)
Zone 5 Auto restore (PIR, VIPER)
Zone 6 Nothing selected (i.e., full set only door contact)
Zone 7 PA/auto restore (Pendant or hand-held PA)
Zone 8 Fire/auto restore
All other defaults are shown in the Engineer Program Command list by a ‘y’.
Engineering Program Commands
To change: Key in: Then: Notes Default
Engineer Access Code 20 ENTER nnnn ENTER See note 1 7890
Consecutive Code Jamming 32 ENTER Any* ENTER See note 2 ON
Instant Night Mode 33 ENTER Any* ENTER See note 3 OFF
Remote Set 34 ENTER Any* ENTER Zone 8 LED shows status ON
First Zone Lockout 35 ENTER Any* ENTER See note 4 ON
Part Set Exit Timer 41 ENTER 1 ENTER = 10 seconds
2 ENTER = 20 seconds y
3 ENTER = 40 seconds
4 ENTER = 60 seconds
5 ENTER = Continuous
6 ENTER = Instant (1.5s bleep
followed by 20s silent)
Bell Duration Timer 42 ENTER 1 ENTER = 1.5 mins
2 ENTER = 3 minutes
3 ENTER = 5 minutes y
4 ENTER = 10 minutes
5 ENTER = 15 minutes
6 ENTER = 20 minutes
7 ENTER = Continuous
8 ENTER = 10s (for testing only)
Entry Timer 43 ENTER 1 ENTER = 10 seconds (see note 5)
2 ENTER = 20 seconds y
3 ENTER = 40 seconds
4 ENTER = 60 seconds
Full Set Exit Timer 44 ENTER 1 ENTER = 10 seconds
2 ENTER = 20 seconds y
3 ENTER = 40 seconds
4 ENTER = 60 seconds
5 ENTER = Continuous
6 ENTER = Final door or 60 seconds
Engineering Program Commands 4600