496339 Issue 1 9 of 44
Wiring FSL Detectors
Each FSL zone is a ‘Fully Supervised Loop’ using a two wire closed loop. The
loop uses two resistors of different values to differentiate between ‘Circuit’
and ‘Tamper’ signals: a 2K2 (2.2K) resistor fitted in series at the end of the
wired loop (EOL-End-Of-Line), and a 4K7 (4.7K) resistor fitted across the
alarm contact, see Figure 6.
Figure 6. Connections for Single Alarm Contacts and Tamper Wiring.
Wiring External Sounders
Figure 7 shows the connections for a typical external sounder (SAB). O/P1 is
permanently programmed as a Bell output. Use Menu 51 in Installer pro-
gramming mode to select normally energised or normally de-energised, and
to program a Strobe output.
If the cable to the external sounder is longer than 50m then some makes of
sounder may cause a tamper when activated. To overcome this problem
double up the wires between the -ve Hold Off on the sounder and the Aux -ve
connection on the panel. If more than one external sounder is being con-
nected, then consult the sounder manufacturer on how to wire the tamper
return circuit.
Figure 7. External/Internal Sounder Connection
8136 Wiring FSL Detectors