10 of 14 496334 Issue 1
To change: Key-in: Notes Default
Bell Duration 42 1 1.5 minutes
2 3 minutes
3 5 minutes
4 10 minutes
5 15 minutes
6 20 minutes Y
7 nil
Entry Time 43 1 10 Seconds Y
2 20 seconds
3 30 seconds
4 45 seconds
5 60 seconds
6 120 seconds
Exit Time 44 0 Continuous (exit terminate only)
1 10 Seconds Y
2 20 seconds
3 30 seconds
4 45 seconds
5 60 seconds
6 120 seconds
CSID Code 50 n...n Seed code for remote reset
Available from Jan 1993 on all models.
Area B final exit response 60 0 Final exit Y
1 Normal alarm
Area B Entry route 61 0 Entry route Y
1 Start entry timer
Area B Exit mode 62 0 As full set
1 Quick set (10s) Y
2 Instant set
3 Deferred set
Area B Alarm response 63 0 Keypad sounders only
1 Internal and keypad sounders Y
2 All sounders, no comms
3 Full alarm (comms and sounders)
Area C final exit 70 see 60
Area C Entry route 71 see 61
Area C Exit mode 72 see 62
Area C Alarm response 73 see 63
Event log 90 1 View earlier events
3 View later events
Test External Bells 91 Bell output operates
Clear Bell test ends
Test Strobe 92 Strobe output operates
Clear Strobe test ends
Test Internal sounder 93 Internal sounder operates
Clear Internal sounder test ends
Engineer Program Commands 9800
Comentários a estes Manuais