496334 Issue 1 11 of 14
To change: Key-in: Notes Default
Test keypad sounder 94 Keypad sounder operates
Clear Keypad sounder test ends
Test output 1 95 Programmable output 1 operates
Clear Output 1 test ends
Test output 2 96 Programmable output 2 operates
Clear Output 2 test ends
Walk Test 97 Zone LED and sounder operate when
circuit open
Clear End walk test
Load defaults 98 Load defaults
Leave programming 99
Leaving Programming Mode
When all programming has been completed:
1. Key-in ‘99’ at the keypad.
The display clears and the Day LED is ON.
The system is now in user mode.
Note: If there is a fault on the system , for example an open tamper circuit, the
display shows this and will not return to Day mode. Press
Y
(Clear) and rectify
the faults.
Engineer Reset
To perform an Engineer Reset:
1. Check that the display is showing the alarm condition. (Note: if the
display shows “rr”, Press Clear twice.)
2. Key in 0 followed by the Engineer’s code (default 7890), followed by 99.
The display goes blank and the Day LED glows.
Re-Entering Programming Mode
“Initial Power Up” describes how to enter programming mode for the first time
in a new installation. If you wish to enter programming mode at any other
time:
1. Make sure the system is unset.
2. Press 0, then key in the Engineer’s code (default 7890).
The keypad gives an intermittent tone.
3. Open the end station lid.
The display shows “E” (for ‘engineer’) and the intermittent tone stops.
You are now in programming mode.
9800 Leaving Programming Mode