496334 Issue 1 7 of 14
Programming
Initial Power Up
When all wiring is complete, power up the system for the first time as follows:
1. Ensure that the keypad(s) and detectors are securely fitted and their
tamper switches closed.
2. Connect the battery and then close the case.
3. Switch on the mains power. Ignore any tones from the internal and
keypad sounders.
4. Go to a keypad and key in 1234.
5. Key in 0 followed by 7890 (the default Engineer’s code).
The keypad gives an intermittent tone.
6. Open the end station lid. (If the lid is already open, close and open the
tamper switch.)
The displays shows “E” (engineer).
You are now in programming mode.
Programming Commands
When delivered from the factory the control unit already has default program
settings. To change the default programming you must be in programming
mode. Then:
1. Key in the appropriate command number.
The display shows the current value of the command.
2. Key in digits to select the value you require.
The display shows a code giving the new value.
3. Press Clear to store the new value of the command.
If at any time you change your mind, repeat step 1 to 3. The table on the
following pages shows the commands and their options. ( A y next to a
command value shows that it is the factory default.)
The factory default access codes are:
Engineer Code 7890
Access Code User 1 1234
Access Code 2 to 4 AAAA (inactive)
Access Code 3 BBBB (inactive)
Access Code 4 CCCC (inactive)
Duress Code OMIT, OMIT, OMIT, OMIT (inactive)
Note: The factory default Access Codes 02 to 04 and the Duress Code must be
changed by USER 1 to a four digit number to activate them.