2 of 14 496334 Issue 1
Introduction
The 9800 Alarm Control Panel comprises a control unit in a shielded case,
and up to four separate keypads.
The control unit provides:
° Connections for up to eight Closed Circuit zones.
° Connections for four outputs (external sounder, strobe, and two fully
programmable outputs).
° Connections for up to four 9825 Keypads.
° Pins for fitting a plug-on communication device. Any device that
complies with the Scantronic plug-on footprint can be fitted.
° Internal sounder loudspeaker output with electronically generated
Chime, Alarm and Fire tones.
The programming interface is arranged as a set of two-digit numbered
commands.
The system can provide for up to 4 separate users. User facilities include:
° Three different security levels (full set and two part sets) which can be
programmed by the installer.
° User programmable Duress code.
° Keyswitch setting/unsetting.
Technical Specifications
General
Operating temperature = -10 °C to + 40 °C.
Humidity = Up to 80% non-condensing.
Dimensions = h x w x d 300 x 300 x 75 mm.
Weight = 4.85 Kg (excl battery).
Standby Battery = 12 Volt, 6.0Ah rechargeable lead-acid, Gel
Type battery.
Power Supply
The total current available from the control unit is as follows:
System output current = 800mA (Ambient Temp. 20 °C).
Control unit pcb = 60mA quiescent.
= 500mA active (when driving standard
external bell).
Each 9825 Remote Keypad = 20mA quiescent.
= 60mA active.
9800