496334 Issue 1 3 of 14
Standard 9066 SAB Module = 40mA.
Plug-on 9056 Communicator = 40mA.
Keypad Wiring
Recommended maximum distances for the remote keypads from the control
unit, using standard alarm cable is 100 metres for the star configuration.
Outputs
OP1, OP2, Bell, Strobe = 500mA. Transistorised outputs capable of
driving a relay.
9825 Keypad Addressing
Before connecting the keypad(s) to the system, the engineer must set the
address of each keypad. Each keypad in a system must have a different
address number to ensure that the control unit can correctly identify them.
To set the address:
1. Ensure the system is powered down.
2. Open the keypad and identify the four position DIP switch on the keypad
pcb, see Figure 1 below. Note that each switch is numbered 1 to 4. The
numbers correspond to the keypad address.
Figure 1. Keypad Address Switch
3. Select one switch and move it to the ON position (up). Make sure all the
other switches are OFF (down). The keypad now has the address given
by the switch that is ON.
Adjusting Keypad Sounder Volume
You can alter the volume of the keypad sounder by adjusting the potentio-
meter located next to the sounder. See Figure 1. When first installing the
keypad set the potentiometer midway using a small screwdriver.
9800 9825 Keypad Addressing